Polarimeters
Author: the photonics expert Dr. Rüdiger Paschotta (RP)
Content quality and neutrality are maintained according to our editorial policy.
Definition: instruments for measuring the rotation angle of optical polarization caused by optically active substances
Categories:
Purchasing: see our Buyer's Guide page for polarimeters – buyer-oriented background information, selection criteria and supplier list
Concept tree
- optical metrology instruments
Related topics
Summary of this article
A polarimeter is an optical instrument for precisely measuring the angle of rotation of the polarization of light, which occurs when light passes through an optically active substance. This in-depth article explains the working principle and typical applications.
The basic setup involves a light source, a polarizer to create linearly polarized light, the sample, and a second rotatable polarizer (analyzer) used to determine the new polarization angle by finding the minimum light transmission. For higher accuracy, refined techniques like the Lippich method are used, which rely on comparing the brightness of two beam parts rather than finding a minimum.
Modern polarimeters are often automated, using motorized analyzers or Faraday rotators for fast and highly accurate measurements. The article also discusses practical aspects like the need for quasi-monochromatic light and precise temperature control, as the optical rotation is often wavelength- and temperature-dependent.
Key applications include determining the concentration of substances, most famously sugar (using instruments called saccharimeters), and analyzing mixtures of enantiomers (chiral molecules) in chemical research and industries like pharmaceuticals.
(This summary was generated with AI based on the article content and has been reviewed by the article’s author.)
What is a Polarimeter?
A polarimeter is an optical instrument with which one can accurately measure the angle by which the polarization of light is rotated e.g. when it passes through an optically active medium (containing chiral molecules).
Operation Principle of Polarimeters
The basic operation principle of a polarimeter comprises the following:
- One generates light with an accurately prepared linear polarization state, usually by passage through a polarizer.
- That light is sent through the optically active sample, which somewhat rotates the polarization direction.
- After passage through the sample, one detects the modified orientation of the polarization by passing the light through another linear polarizer (called the analyzer), which can be rotated around the beam axis.
The simplest method is to rotate the analyzer into a position for which the transmission of optical power is at its minimum (which should be only a very tiny fraction of the input power), and to register the angular orientation where that condition is met.
Figure 1 shows the basic optical setup of such an instrument. The used method is called polarimetry.
Details and Refinements of the Method
The first polarizer is in principle not necessary if the used light source already emits linearly polarized light – for example, that is the case for various kinds of lasers. However, the polarizer may still be used to obtain a reliably high degree of linear polarization with a well-defined orientation.
Requirements on Components and Sample
The used polarizers should have a high degree of extinction. In practice, one often uses Nicol prisms or similar high-quality devices.
The optical mount of the analyzer must be made with precise fine mechanics and equipped with a fine scale to allow the user to accurately determine the angular orientation of the polarizer's axis.
It is preferable that the investigated sample is quite homogeneous, since otherwise one would not obtain a uniform amount of polarization rotation, and the measurement accuracy would be reduced.
Source Bandwidth
The light source should not have a too large optical bandwidth because the degree of optical activity may vary within that bandwidth, and that would lead to some broadening of the observed intensity minimum and thus to a reduced accuracy of the measurement. Nevertheless, one does not need to use a laser as a quasi-monochromatic light source; instead, one may also use a light-emitting diode LED, for example, or a substantially more broadband light source (e.g. an incandescent lamp) in combination with an optical bandpass filter (e.g. an interference filter).
Lippich Method
An improved method, based on an intervention of the Austrian physicist Ferdinand Franz Lippich in the late 19th century, uses an additional optical element which introduces some rotation of the polarization direction for about half of the beam area after the polarizer. One can then not obtain complete darkness after the analyzer for any orientation. Instead, one adjusts the analyzer for equal brightness of both areas. Lippich's approach allows for more accurate measurements, essentially because the brightness difference depends linearly on the angular deviation, while the brightness in the simple polarimeter as described above depends on the square of the angular deviation from the minimum intensity point.
Automated Analyzers
Some advanced polarimeters can perform automated measurements, where the analyzer is rotated and the device itself determines the analyzer orientation for minimum optical power transmission. Using a precise mechanical drive (with fine resolution and a high degree of reproducibility) and optimized software (e.g. utilizing data for multiple orientations, to which a curve can be fitted), one can not only obtain a substantially higher measurement accuracy than for manual measurements, but also a much reduced measurement time of e.g. one second instead of multiple seconds. Such an instrument may also be quite simple to handle and less prone to possible errors of the operator. The amount of optical activity, as calculated from the measured rotation angle and length of the sample, may directly appear on a digital display.
There are instruments where the analyzer is continuously rotating with a constant angular velocity, and the phase of the resulting output signal is used to derive the optical activity.
Instead of a rotatable analyzer, one may use a Faraday rotator in combination with a wire coil, mounted before the analyzer, which in that case does not need to be rotated. One may then determine the required electric current through the coil which produces a suitable amount of optical activity through the Faraday effect, such that minimum transmission through the analyzer is achieved. That method can be both quite accurate and fast.
Such a coil-driven Faraday rotator is a kind of polarization modulator. An additional small alternating current can modulate the polarization direction periodically, so that the null point can be found with phase-sensitive detection: at the null point, the signal component at the modulation frequency vanishes, and its sign on either side indicates the direction of the required correction. Other instruments, e.g. for measuring circular dichroism, use photoelastic modulators with lock-in detection.
Temperature Dependence and Control
The specific optical rotation of a substance is temperature-dependent. For many substances, the rotation changes significantly with temperature, necessitating precise temperature control during measurement to ensure accuracy and reproducibility. Modern digital polarimeters often feature built-in temperature control systems, such as Peltier elements, to maintain the sample at a standard temperature (typically 20 °C or 25 °C) or to compensate mathematically for known temperature coefficients.
Measurement Scales
While general-purpose polarimeters measure the angle of rotation in degrees, specific industries use specialized scales. The most common is the International Sugar Scale, where the unit is degrees Z. This scale is defined such that 100 ˆZ corresponds to the optical rotation of a standard sucrose solution (26 g in 100 ml water) at 20 °C and a wavelength of 589.44 nm (sodium D line) in a 200 mm tube. Instruments calibrated specifically for this scale are often referred to as saccharimeters.
Applications of Polarimeters in Research and Industry
Polarimeters can be used in scientific research and in industry wherever the magnitude of optical activity of a substance must be determined. If the specific rotation of the substance is already known, and it is e.g. dissolved in water, the concentration of the substance can be determined from the measured degree of optical activity. For example, with that method one can accurately and quickly determine the concentration of sugar in water, which is of practical interest e.g. in the sugar industry and for the production of wines. Such instruments for measuring sugar concentrations are called saccharimeters.
In some cases, a substance is a mixture of two enantiomers, i.e., versions of molecules which are mirror images of each other. Each of them has an optical activity of one sign, i.e., the two enantiomers rotate the polarization direction in different directions, and the angular rotation contributions from both enantiomers simply add up – for example to zero in the case of a racemate, i.e., a mixture with equal densities of both enantiomers. In many other respects, such as refractive index and light absorption, those types of molecules behave in identical ways. The measurement of optical activity can then be used to determine the ratio of concentrations of both versions. In a biological context, however, one often essentially has only one of the two possible enantiomers, and optical activity measurements are then more likely to be used simply to measure the concentration of that version.
Question not answered? Ask our AI-based search:
Purchasing
For professional purchasing, our buyer's guide for polarimeters explains additional buyer-oriented technical background and suggests selection criteria: Measurement scales, Measurement range, Accuracy, Wavelength(s), Light source, Temperature control, Sample cell compatibility, Measurement time, Regulatory compliance features. It also lists 14 suppliers of polarimeters. One of these shows their product descriptions as sponsored content:

The polarization analyzers of our SK010PA series are universal measurement and test systems for coupling laser beam sources into polarization-maintaining fiber cables. Main features include the determination of the state of polarization (SOP) with all four Stokes parameters, PER (polarization extinction ratio) and the degree of polarization (DOP).
Frequently Asked Questions
This FAQ section was generated with AI based on the article content and has been reviewed by the article’s author (RP).
What is a polarimeter?
A polarimeter is an optical instrument used to measure the angle by which the polarization of light is rotated when passing through an optically active medium, which contains chiral molecules.
How does a simple polarimeter work?
It first produces linearly polarized light with a polarizer. This light passes through the sample, where its polarization direction is rotated. A second, rotatable polarizer (the analyzer) is then used to determine the rotation angle by finding the new orientation for minimum light transmission.
What are the main applications of polarimeters?
They are used to determine the concentration of optically active substances, such as sugar in solutions (using saccharimeters). They are also used in chemistry to determine the ratio of two enantiomers (mirror-image molecules) in a mixture.
Why is it better to use light with a small bandwidth in a polarimeter?
The amount of polarization rotation (optical activity) can be wavelength-dependent. Using broadband light would cause different colors to be rotated by different amounts, which would blur the measurement and reduce its accuracy.